The ESxxxC Standard and High Energy Pyroelectric Sensors are designed to measure pulsed coherent and incoherent sources. Pyroelectric sensors are not suited for CW measurements, as they convert energy from light pulses into voltage pulses. A black broadband or ceramic coating is used for low or high power measurements, respectively. Large sensor areas from Ø11 mm to Ø45 mm allow easy alignment. The energy sensors features BNC connectors for use with an oscilloscope, as well as standard power meter connectors which contain NIST and PTB-traceable calibration data.
Thorlabs offers a recalibration service for these energy sensors, which can be ordered below (see Item # CAL-THPY).
Item #a | ES111C | ES120C | ES145C | ES220C | ES245C |
---|---|---|---|---|---|
Sensor Image (Click the Image to Enlarge) | |||||
Input Aperture Size | Ø11 mm | Ø20 mm | Ø45 mm | Ø20 mm | Ø45 mm |
Wavelength Range | 0.185 - 25 µm | ||||
Energy Range | 10 µJ - 150 mJ | 100 µJ - 500 mJ | 500 µJ - 2 J | 500 µJ - 3 J | 1 mJ - 15 J |
Detector Type | Pyroelectric Energy Sensor with Black Broadband Coating | Pyroelectric Energy Sensor with Ceramic Coating | |||
Resolution | 100 nJ | 1 µJ | 1 µJ | 25 µJ | 50 µJ |
Linearity | ±1% | ||||
Measurement Uncertainty | ±5% @ 0.185 - 25 µm | ||||
Housing Dimensions | Ø36 mm x 16 mm | Ø50 mm x 18 mm | Ø75 mm x 21 mm | Ø50 mm x 18 mm | Ø75 mm x 21 mm |
Active Detector Area | 95.0 mm2 | 314.2 mm2 | 1590.4 mm2 | 314.2 mm2 | 1590.4 mm2 |
Cable Length | 1.5 m | ||||
Post Mounting | 8-32 Mounting Thread, 8-32 and M4 Insulating Adapters Included | ||||
Cage Mounting | N/A | Four 4-40 Threadings for 30 mm Cage Systems | N/A | Four 4-40 Threadings for 30 mm Cage Systems | N/A |
Compatible Consoles | |||||
Compatible Interfaces |
Sensor Type | Sensor Item #s |
---|---|
Thermal Power | S175C, S302Ca, S305Ca, S310Ca, S314Ca,S322C, S350C, S370C, S401C, S405C, S415C, S425C, S425C-L, S470C, PM160T, PM160T-HP, PM16-401, PM16-405 |
Pyroelectric Energy | ES111C, ES120C, ES145C, ES220C, ES245C |
Thorlabs offers recalibration services for our Thermal Power and Pyroelectric Energy Sensors. To ensure accurate measurements, we recommend recalibrating the sensors annually. Recalibration of a single-channel power and/or energy meter console or interface is included with the recalibration of a sensor at no additional cost.
Please note that the CAL-THPY recalibration service cannot be used for our Thermal Position & Power Sensors; recalibration for these sensors can be requested by contacting Tech Support.
The table to the upper right lists the sensors for which the CAL-THPY recalibration service is available. Please enter the Part # and Serial # of the sensor that requires recalibration prior to selecting Add to Cart.